Company Add:
7th floor,NO.2 Building,Tenghongxing Technology Park,Jiazitang Towm,Guang Ming New Distirct,shenzhen
Tel :86 -755-2238 5040
Fax :86 -755-6130 8917
http://www.santakpower.com.cn7th floor,NO.2 Building,Tenghongxing Technology Park,Jiazitang Towm,Guang Ming New Distirct,shenzhen
Products | Location:Home > Products |
True double-conversion online ups
High performance DSP technology guarantee
50Hz/60Hz frequency converter mode
Eco mode operation for energy saving (ECO)
Accepts dual power inputs
Emergency power off function(EPO)
Generator compatible
SNMP+USB-RS-232 mutiple communications
3-stage extendable charging design for optimized battery performance
Adjustable battery numbers
Maintenance bypass available
Optional N+X parallel redundancy
Standard online ups and online lead aircraft ups in one integrated unit
Model
|
3C10K(S) | 3C15K(S) | 3C20K(S) | 3C30K(S) | ||
Phase | 3 phase in single phase out | |||||
Capacity | 10000VA/8000W | 15000VA/12000W | 20000VA/16000W | 30000VA/24000W | ||
Input |
Rated voltage
|
3*400VAC (3ph+N) | ||||
Voltage range | 305-478VAC(3-phase)@100% load190-520 VAC(3-phase)@50% load | |||||
Frequency range | 46-54Hz or 56-64Hz | |||||
Power Factor | ≥0.99 @100% load | |||||
Output | Output voltage | 208/220/230/240VAC | ||||
Voltage range(Batt.mode) | ±1% | |||||
Frequency range
(Synchronization correction range)
|
46-54Hz@50Hz/56-64Hz@60Hz | |||||
Frequency range (Batt.mode) | 50hz ± 0.1hz or 60hz ± 0.1hz | |||||
Surge ratio | 3:1(max) | |||||
Harmonic distortion |
≤2% THD( linear load); ≤5%THD(Non-linear load |
|||||
Transfer time |
AC to DC
|
0
|
||||
Inverter to Bypass | 0 | |||||
Wave form |
Pure sine wave
|
|||||
Efficiency
|
AC mode
|
89% | 89% | 89% | 90% | |
DC mode | 86% | 88% | 87% | 89% | ||
Battery |
Standard model machine
|
Battery type
|
12V9AH | |||
Quantity
|
20(18-20
Adjustable)
|
20*2 (18-20
Adjustable)
|
20*2 (18-20
Adjustable)
|
20*3 (18-20 Adjustable) |
||
Standard charging time
|
9 hours charge to 90% | |||||
The maximum charge current
|
1A | 2A | 4A | |||
Charging voltage
|
273VDC±1% (Based on 20 Batteries) | |||||
Long-term model machine |
Battery type
|
Depending on the application provider
|
||||
Quantity
|
16(192V) | 16(192V) | 20(240V) | |||
The maximum charge current
|
4A | 4A | 12A | |||
Charging voltage
|
13.65VDC ±1% (Based on 1 Battery) |
273VDC±1% (Based on 20 Batteries) |
||||
Display description
|
LED or lcd |
Load size , battery capacity, AC mode,DCmode,bypass mode,
Fault Indication
|
||||
Warning sound
|
DC node | Every 4 seconds a sound | ||||
Warning sound | Every 1 second a sound | |||||
Overload | Every0.5 second a sound | |||||
Error | Continuous ringing | |||||
Physical properties | Standard models | Dimension(D*W*H)mm | 592*250*576 | 815*250*826 | 815*300*1000 | |
Net weight(kgs) | 82 | 164 | 234 | |||
Long-term models | Dimension(D*W*H)mm | 592*250*576 | 592*250*576 | 815*250*826 | ||
Net weight(kgs) | 28 | 40 | 64 | |||
Environment | Humidity | 20-90% RH @ 0-40°C(No condensation) | ||||
Noise | <58dB@1Meter | <60dB@1Meter | <65dB@1Meter | |||
Control Management
|
Smart RS-232/USB
|
Support windows ® 2000/2003XP/Vista/2008,windows®7/8,Linux,Unix,and MAC
|
||||
Optional SNMP
|
Power management support SNMP management and network management
|
Copyright@2011 Shenzhen Huayunzhimei power Equipment Co.,Ltd All rights reserved All Rights Reserved.